INDUSTRIAL PRODUCT
CT Scan Machine Plastic System Cabinet Rear Mould and Moulding Service
₹1,300.00
CT Scan Machine Plastic System Cabinet Rear Mould and Moulding Service | Renovator Appliances Ltd
Product Overview
Renovator Appliances Ltd manufactures precision Plastic Injection Moulds and provides injection moulding solutions for CT Scan Machine Plastic System Cabinet Rear components used as rear enclosure sections of CT scanner system cabinets.
The System Cabinet Rear forms the rear-facing plastic enclosure or cover section of the designated CT system cabinet. It helps protect enclosed components while providing interfaces for ventilation, cable routing, connectors, service access, mounting, and connection with adjoining cabinet panels.
The mould is developed according to the cabinet dimensions, rear profile, internal component arrangement, ventilation requirements, cable-routing layout, mounting structure, and service-access requirements. The rear component can be customized with ventilation grilles, cable-entry openings, connector cut-outs, mounting bosses, locating ribs, screw features, clips, snap-fits, and other equipment-specific details.
Key Features
Precision injection moulding for CT scanner system cabinet rear components
Customized rear cabinet profile and enclosure geometry
Proper fitment with adjoining cabinet panels
Integrated ventilation openings where required
Cable-entry and routing provisions
Connector-access openings where required
Internal component clearance
Reinforced mounting sections
Integrated screw bosses and locating features
Screw, clip, or snap-fit assembly options
Controlled wall thickness for dimensional stability
Smooth and consistent external surface
Customized colour, texture, and surface finish
Suitable for prototype and volume production
OEM and ODM manufacturing support
Industrial Applications
| Application | Use of CT Scan Machine Plastic System Cabinet Rear |
|---|---|
| CT Scan Machine | Forms the rear enclosure section of the designated system cabinet |
| CT System Cabinet | Protects and encloses designated internal components |
| Medical Imaging Equipment | Provides a finished rear cabinet interface |
| CT Electronics Cabinet | Supports ventilation, cable routing, and component protection |
| Diagnostic Imaging Systems | Provides customized cabinet enclosure construction |
| Hospital CT Equipment | Provides rear access and protective enclosure features |
| OEM CT Systems | Manufactured according to customer-specific cabinet designs |
Manufacturing Process
1. Product Design & Development
The CT Scan Machine Plastic System Cabinet Rear is developed according to the customer's CAD drawing, 3D model, physical sample, complete cabinet assembly, or equipment specifications.
The design is reviewed for overall cabinet dimensions, rear profile, adjoining panel interfaces, internal component clearance, ventilation requirements, cable and connector locations, mounting points, service access, and fastening arrangements.
For large rear cabinet surfaces, wall thickness, rib placement, draft angles, and mounting locations are evaluated to help maintain dimensional stability and reduce warpage.
2. Plastic Mould Design
The injection mould is designed around the complete rear cabinet geometry. Cores and inserts can be incorporated for ventilation openings, cable passages, connector cut-outs, mounting bosses, screw holes, locating ribs, clips, snap-fits, and service-access features.
Parting lines, gate locations, runner systems, cooling channels, ejector arrangements, draft angles, and shrinkage allowances are optimized according to the housing geometry and selected plastic material.
For broad or large rear panels, balanced filling and cooling are considered to minimize warpage, sink marks, flow marks, and dimensional distortion.
3. Mould Manufacturing
Mould components are manufactured using suitable mould steels such as P20 Steel, H13 Steel, or S136 Steel, depending on production quantity, expected mould life, selected plastic material, surface-finish requirements, and component complexity.
CNC machining, EDM, drilling, grinding, polishing, precision fitting, and mould assembly are used to achieve the required cavity and core geometry.
4. Injection Moulding
The selected plastic material is processed under controlled injection moulding conditions. Injection temperature, filling speed, pressure, holding pressure, cooling time, and cycle parameters are adjusted according to the selected plastic grade and cabinet rear geometry.
Controlled processing helps maintain consistent dimensions, ventilation openings, cable passages, mounting features, surface appearance, and fitment with the complete CT system cabinet.
5. Finishing & Assembly Preparation
After moulding, the cabinet rear components are inspected for flash, gate marks, sink marks, short shots, warpage, and surface imperfections. Gate trimming and edge finishing are performed where required.
The moulded rear section can be prepared for installation of cables, connectors, ventilation components, mounting hardware, access features, and adjoining cabinet panels.
6. Quality Inspection
Finished CT Scan Machine Plastic System Cabinet Rear components are checked for overall dimensions, rear profile, mounting features, ventilation openings, cable passages, internal clearances, surface finish, and fitment with adjoining cabinet sections.
Trial assembly can be performed to verify panel alignment, mounting stability, cable clearance, ventilation provisions, and service-access requirements.
Raw Materials
| Material | Suitability for CT Scan Machine Plastic System Cabinet Rear |
|---|---|
| ABS | Suitable for rigid cabinet rear components requiring good appearance and dimensional stability |
| PC+ABS | Suitable where improved impact resistance and dimensional performance are required |
| PC | Suitable where higher impact and thermal performance are required |
| PP | Lightweight option for suitable enclosure applications |
| HIPS | Suitable for selected rigid and cost-sensitive cabinet applications |
| PBT | Suitable where dimensional stability and mechanical performance are important |
| Flame-Retardant ABS | Suitable where specified flame-performance requirements apply |
| Flame-Retardant PC+ABS | Suitable where enhanced flame-performance characteristics are required |
| Engineering-Grade Plastic | Suitable for demanding mechanical, dimensional, thermal, or environmental requirements |
The final plastic grade should be selected according to mechanical loads, operating temperature, cleaning and disinfectant exposure, dimensional stability, surface requirements, flame-performance requirements, and applicable medical-equipment specifications.
Quality Control
Renovator Appliances Ltd performs quality checks throughout mould development and injection moulding production. Inspection can include:
Plastic material and grade verification
Mould cavity dimensional inspection
Overall cabinet rear dimensions
Rear profile and curvature
Front-to-rear cabinet interface dimensions
Side-panel mating dimensions
Mounting-boss position
Screw-hole dimensions where applicable
Locating-rib accuracy
Clip and snap-fit accuracy
Ventilation opening dimensions
Cable-entry opening dimensions
Connector cut-out dimensions where applicable
Internal component clearance
Wall-thickness consistency
Service-access dimensions
Warpage and deformation inspection
Flatness and straightness inspection
Sink-mark inspection
Short-shot inspection
Flash and burr inspection
Surface-finish inspection
Colour consistency
Adjoining-panel fitment
Trial assembly inspection
Batch-to-batch dimensional consistency
Buyer Guide
When ordering a CT Scan Machine Plastic System Cabinet Rear Mould and Moulding Service, buyers should provide a CAD drawing, 3D model, physical sample, complete system cabinet assembly, or equipment specifications. Important requirements include:
Overall cabinet dimensions
Rear profile and curvature
Adjoining front and side panel dimensions
Internal component dimensions
Ventilation requirements
Cable-entry and routing requirements
Connector locations and dimensions
Mounting arrangement
Screw, clip, or snap-fit requirements
Mounting-boss requirements
Locating-feature requirements
Service-access requirements
Required wall thickness
Internal clearance requirements
Surface texture and finish
Colour requirements
Cleaning and disinfectant requirements
Operating temperature
Plastic material and grade
Flame-performance requirements where applicable
Expected production quantity
Required mould life
Prototype requirements
Mass-production requirements
OEM or ODM assembly requirements
For CT scanner equipment, the system cabinet rear should be validated as part of the complete medical-device assembly for mechanical fitment, thermal conditions, cleaning requirements, EMC considerations, imaging-related clearances, radiation safety, and applicable regulatory requirements. The plastic cabinet rear should not be assumed to provide radiation shielding or define the X-ray beam unless specifically engineered, tested, and validated for that purpose.
Why Choose Renovator Appliances Ltd?
Advanced Injection Moulding Facility
Renovator Appliances Ltd provides controlled plastic injection moulding for precision CT scanner system cabinet components, rear panels, covers, ventilation components, and related enclosure parts.
In-House Mould Manufacturing
In-house mould manufacturing provides control over cabinet geometry, ventilation openings, cable passages, mounting features, internal clearances, cooling, ejection, and surface-finish requirements.
OEM & ODM Manufacturing
Customized CT Scan Machine Plastic System Cabinet Rear moulds and moulded components can be developed according to customer drawings, samples, cabinet layouts, and equipment specifications.
Quality Assurance
Dimensional, visual, material, surface, opening, ventilation, and assembly checks help maintain consistent cabinet rear quality and fitment.
Cost-Effective Manufacturing
Integrated mould manufacturing and injection moulding support prototype development, pilot production, and regular commercial quantities.
Frequently Asked Questions
1. What is a CT Scan Machine Plastic System Cabinet Rear?
It is a moulded plastic rear enclosure component designed for a designated CT scanner system cabinet, providing protection and interfaces for ventilation, cable routing, mounting, and service access.
2. Can the system cabinet rear be customized for a specific CT scanner?
Yes. The rear profile, dimensions, ventilation openings, cable passages, connector cut-outs, mounting features, service access, and internal clearances can be customized according to the cabinet design.
3. Can ventilation and cable-routing features be integrated into the rear component?
Yes. Ventilation slots, grilles, cable-entry openings, connector interfaces, locating features, and mounting provisions can be incorporated into the injection mould according to the equipment requirements.
4. Which plastic materials can be used for the system cabinet rear?
ABS, PC+ABS, PC, PP, HIPS, PBT, flame-retardant ABS, flame-retardant PC+ABS, and suitable engineering plastics can be considered according to mechanical, thermal, dimensional, cleaning, surface, and regulatory requirements.
5. Can Renovator manufacture both the mould and system cabinet rear?
Yes. Renovator Appliances Ltd can provide mould manufacturing and injection moulding solutions for customized CT Scan Machine Plastic System Cabinet Rear production, supporting OEM and ODM requirements.
- SKU
- REN-CF26683F41F4865B621BDBDA