R. Industrial Supply PRODUCTS · PARTS · OEM

INDUSTRIAL PRODUCT

Mammography Machine Plastic Paddle Holder Mould and Moulding Service

SKU: REN-266A86D900D59CFF016AD842 Model: MMPPH

₹300.00

Mammography Machine Plastic Paddle Holder Mould and Moulding Service | Renovator Appliances Ltd

Product Overview

Renovator Appliances Ltd manufactures precision Plastic Injection Moulds and provides injection moulding solutions for Mammography Machine Plastic Paddle Holder components used in designated mammography compression-paddle assemblies. The paddle holder provides a mounting and positioning interface between the compression paddle and its supporting or positioning mechanism.

The mould is developed according to the required paddle dimensions, holder geometry, mounting interface, attachment method, load requirements, positioning accuracy, internal clearances, and surrounding assembly configuration. The holder can be customized with mounting bosses, locating features, retaining clips, screw holes, pivot interfaces, guide features, and reinforcing ribs according to the equipment design.

Key Features

  • Precision injection moulding for mammography paddle holders

  • Customized holder geometry according to paddle design

  • Accurate paddle mounting and positioning interface

  • Reinforced attachment areas for mechanical loading

  • Integrated locating bosses, ribs, clips, or guides

  • Screw-fit, snap-fit, or clip-fit assembly options

  • Pivot or sliding interfaces where required

  • Controlled wall thickness for dimensional stability

  • Accurate alignment with the compression mechanism

  • Smooth finished surfaces

  • Customized colour and surface texture

  • Suitable for prototype and volume production

  • Supports OEM and ODM manufacturing requirements

Industrial Applications

ApplicationUse of Mammography Machine Plastic Paddle Holder
Mammography Compression AssemblySupports and positions the compression paddle
Mammography Imaging SystemProvides the paddle mounting interface
Breast Compression MechanismConnects the paddle with the designated support structure
Screening Mammography EquipmentSupports customized paddle attachment arrangements
Diagnostic Mammography EquipmentMaintains paddle positioning within the specified assembly
OEM Mammography EquipmentManufactured according to customized machine designs

Manufacturing Process

1. Product Design & Development

The Mammography Machine Plastic Paddle Holder is developed according to the customer's CAD drawing, 3D model, physical sample, compression-paddle assembly, or equipment specifications. The design is reviewed for paddle dimensions, holder profile, mounting interface, expected mechanical load, attachment method, positioning requirements, movement range, and clearance from surrounding components.

Particular attention is given to the holder's alignment with the compression paddle and supporting mechanism to achieve repeatable assembly and movement.

2. Plastic Mould Design

The injection mould is designed around the holder geometry and its functional mounting features. Suitable parting lines, draft angles, gate locations, cooling channels, ejector arrangements, cores, inserts, and shrinkage allowances are incorporated.

Mounting bosses, screw holes, pivot interfaces, locating ribs, retaining clips, guide features, and snap-fits are designed according to the complete assembly. Reinforced sections are provided where required to handle mechanical loads without excessive deformation.

3. Mould Manufacturing

Mould components are manufactured using suitable mould steels such as P20 Steel, H13 Steel, or S136 Steel, depending on production volume, expected mould life, selected plastic material, surface-finish requirements, and component complexity.

CNC machining, EDM, drilling, grinding, polishing, precision fitting, and mould assembly are used to achieve the required cavity geometry and dimensional accuracy.

4. Injection Moulding

The selected plastic material is processed under controlled injection moulding conditions. Injection temperature, filling speed, injection pressure, holding pressure, cooling time, and cycle time are adjusted according to the selected plastic grade and paddle-holder geometry.

Controlled processing helps maintain mounting-interface accuracy, hole dimensions, alignment features, wall thickness, and dimensional stability.

5. Finishing & Assembly Preparation

After moulding, the paddle holders are inspected for flash, gate marks, sink marks, short shots, sharp edges, warpage, and surface imperfections. Mounting bosses, holes, clips, pivot interfaces, locating features, and retaining sections are checked before assembly.

Where required, the component can be prepared for installation with the compression paddle and designated mammography positioning mechanism.

6. Quality Inspection

Finished Mammography Machine Plastic Paddle Holder components are checked for overall dimensions, mounting-interface accuracy, hole positions, locating features, structural sections, surface finish, and fitment with the associated paddle assembly.

Trial assembly can be performed to verify secure paddle attachment, alignment, movement clearance, retention, and compatibility with the supporting mechanism.

Raw Materials

MaterialSuitability for Mammography Machine Plastic Paddle Holder
PC+ABSSuitable for rigid holders requiring good impact resistance and dimensional stability
ABSSuitable for rigid structural housing and holder applications
PCSuitable where higher impact resistance and dimensional stability are required
PBTSuitable where dimensional stability and thermal performance are required
Nylon / PASuitable for applications requiring higher mechanical strength and wear resistance
Glass-Filled NylonSuitable for demanding structural applications requiring increased rigidity
Flame-Retardant PC+ABSSuitable where specified flame-performance requirements apply
Engineering-Grade PlasticSuitable for demanding mechanical and dimensional requirements
Medical-Grade Engineering PlasticSuitable where applicable medical-device material requirements apply

The final plastic grade should be selected according to mechanical loading, repeated movement, wear, operating temperature, cleaning and disinfectant exposure, dimensional stability, patient-contact proximity, flame-performance requirements, and applicable medical-device specifications.

Quality Control

Renovator Appliances Ltd performs quality checks throughout mould development and injection moulding production. Inspection can include:

  • Plastic material and grade verification

  • Applicable material certification review

  • Mould cavity dimensional inspection

  • Overall holder dimensions

  • Wall-thickness consistency

  • Paddle mounting-interface dimensions

  • Mounting-hole position and diameter

  • Boss dimensions

  • Pivot-hole dimensions where applicable

  • Locating-feature accuracy

  • Guide-feature dimensions

  • Clip and snap-fit accuracy

  • Reinforcing-rib dimensions

  • Paddle alignment

  • Surface-finish inspection

  • Flash and burr inspection

  • Sink-mark and short-shot inspection

  • Warpage and deformation inspection

  • Colour consistency

  • Paddle-holder trial assembly

  • Paddle retention verification

  • Movement and clearance inspection

  • Repeated assembly compatibility where required

  • Batch-to-batch dimensional consistency

Buyer Guide

When ordering a Mammography Machine Plastic Paddle Holder Mould and Moulding Service, buyers should provide the complete paddle-holder design, CAD drawing, 3D model, physical sample, or compression-assembly specifications. Important requirements include:

  • Compression paddle dimensions

  • Paddle mounting-interface dimensions

  • Holder dimensions and profile

  • Mounting-hole dimensions and locations

  • Screw, clip, snap-fit, or pivot requirements

  • Required retaining force

  • Expected mechanical load

  • Movement range where applicable

  • Guide and locating requirements

  • Internal component clearance

  • Required wall thickness

  • Plastic material and grade

  • Cleaning and disinfectant requirements

  • Operating temperature

  • Surface texture and finish

  • Colour requirements

  • Expected production quantity

  • Required mould life

  • Prototype or mass-production requirements

  • OEM or ODM assembly requirements

For mammography equipment, the Paddle Holder should be validated as part of the complete medical-device assembly for mechanical strength, paddle retention, positioning accuracy, movement, repeated-use durability, cleaning and disinfectant exposure, material compatibility, patient-contact proximity, and applicable medical-device and regulatory requirements. The plastic holder should not be assumed to provide radiation shielding or define the X-ray beam unless specifically engineered, tested, and validated for that function.

Why Choose Renovator Appliances Ltd?

Advanced Injection Moulding Facility

Renovator Appliances Ltd provides controlled plastic injection moulding for precision mammography components requiring accurate mounting interfaces, structural features, repeatable dimensions, and consistent surface quality.

In-House Mould Manufacturing

In-house mould manufacturing provides better control over holder geometry, mounting features, cooling, ejection, surface finish, and dimensional accuracy.

OEM & ODM Manufacturing

Customized Mammography Machine Plastic Paddle Holder moulds and moulded components can be developed according to customer drawings, paddle samples, compression mechanisms, and equipment specifications.

Quality Assurance

Dimensional, material, visual, assembly, retention, and movement checks help maintain consistent paddle-holder quality and reliable integration with the mammography compression assembly.

Cost-Effective Manufacturing

Integrated mould manufacturing and injection moulding support efficient production for prototype development, pilot production, and regular commercial quantities.

Frequently Asked Questions

1. What is a Mammography Machine Plastic Paddle Holder?

It is a moulded plastic component designed to hold, position, or connect a compression paddle with its designated supporting or positioning mechanism in a mammography system.

2. Can the paddle holder be customized for a specific compression paddle?

Yes. The holder dimensions, mounting interface, hole positions, clips, pivot features, locating elements, and retaining structure can be customized according to the paddle and equipment design.

3. Can the paddle holder support repeated mechanical movement?

Yes. The holder can be designed with suitable reinforced sections, mounting interfaces, pivot features, and engineering plastics according to the expected movement, load, and service conditions.

4. Which plastic materials can be used for the paddle holder?

ABS, PC+ABS, PC, PBT, Nylon / PA, glass-filled Nylon, flame-retardant PC+ABS, and suitable engineering or medical-grade plastics can be considered according to mechanical, dimensional, thermal, cleaning, and medical-device requirements.

5. Can Renovator Appliances Ltd manufacture both the mould and moulded paddle holder?

Yes. Renovator Appliances Ltd can provide mould design, mould manufacturing, injection moulding, prototype development, quality inspection, and volume production support for customized Mammography Machine Plastic Paddle Holder components.

Product informationSpecifications shown below
Industrial catalogProduct details for business buyers
SKU
REN-266A86D900D59CFF016AD842